,Air-Compressing and Air-Separation

Agriculture, Food & Beverage 12423
Automobile & Transportation 1882
Business Services 763
Chemical 6312
Computer Hardware & Software / Telecommunications 13099
Construction and Real Estate 1955
Electrical Equipment & Supplies / Security & Protection 51474
Environment and Energy 618
Furniture & Furnishings / Woods 1090
Gifts & Crafts / Toys 1800
Home, Industrial & Office Supplies 6044
Jewelry, Eyewear & Timepieces 1873
Machinery and Equipment / Industrial Supplies 62252
Medical, Health & Beauty 2187
Minerals, Metals & Materials 39362
Sports, Leisure & Entertainment 1988
Textiles & Leather Products 11208
_Others 312
trade Join free
trade trade trade
exportexportexport
Add new Product
export export
exportexportexport
Member Login
investment investment
investmentinvestmentinvestment
My Items
investment investment
investmentinvestmentinvestment
Submit URL
investment investment
investmentinvestmentinvestment
Inquiry Basket
investment investment
Suppliers
Suppliers
Berlinkauf Trade Leads / Machinery and Equipment / Industrial Supplies / Air-Compressing and Air-Separation

Definite Purpose Contactor




Previous   Next



Definite Purpose Contactor



Specifications:
1) Name: 1 pole definite purpose contactor
2) Model number: HLC-1N
3) Contact:
a) Arrangements: 1 pole N.O. without shunt
b) Structure: double make contacts
c) Materials: silver cadmium oxide (10% to 30Amp 13% 40Amp)
d) Max. loading rating: see contact rating chart
4) Coil:
a) Coil voltage: 50/60Hz, see coil rating chart
b) Nominal resistance: see coil rating chart
c) Nominal inrush power: [This information will show after login with premium membership], [This information will show after login with premium membership]
d) Coil temperature rise: 65oC max.
e) Class of insulation: 130oC class B
5) Operation:
a) Must operate voltage: 85% of nominal coil valtage or less
(24VAC=75% or less)
b) Must release voltage: 10% to 60% of operate voltage
c) Initial operate time: 20ms typical
d) Initial release time: 10ms typical
e) Bounce time: 0 to 10 ms typical
6) Environment:
a) Temperature range: storage and operating -40 - 65oC
7) Initial dielectric strength:
a) Between contacts and coil: 2,500VAC
b) Between poles: 2,500VAC
c) Between open contacts: 2,500VAC
8) Mechanical data (power pole termination: wire size, tightening torque):
a) #10-32 screw: 16 - 8 AWG, 22Ibf.-in.(2.49Nm)
b) Box lug: 14 - 4 AWG, 40Ibf. -in. (4.52 Nm)
9) Coil termination: dual 0.250 quick connects (6.35mm)
10) Unit weight without optional cover: 7oz (200g/m)
11) Life expectancy: depends upon duty cycle, load, and environmental
conditionals
12) Mechanical life:
a) Design requirement AR1780 = 500,000 operations
b) Min test requirement = 1,000,000 operations at 60 operations per
minute, 50% Duty cycle, 150 F and 110% of nominal coil volatage
13) Electrical life test results:
a) 40 and 50 RLA (resistive load)
b) 250,000 operations make, carry and break 100% pf. 600VAC 30 FLA rated
c) 200,000 operations make LRA 40 to 50% pf., break 125% FLA 75 to 80%
[This information will show after login with premium membership]
d) 250,000 operations make, carry, break 75 to 80% [This information will show after login with premium membership]
e) 250,000 operations make, carry, break 75 to 80% [This information will show after login with premium membership]
40 FLA rated
f) 100,000 operations make LRA 40 to 50% pf., break 125% FLA 75 to 80%
[This information will show after login with premium membership]
g) 250,000 operations make, carry, break 75 to 80%[This information will show after login with premium membership]
h) 300,000 operations make, carry, break 75 to 80%[This information will show after login with premium membership]

Packing: 50pcs/box



Add to basket
More Products in this category
More Products from company
Send Private Message
Tell-a-friend
Add your review

[Contact Information]

Posted by Mr. Kant Huang
e-MailContact company
Address YueQing, Anhui No.178 ShuiZhang West Road
Country
China
Phone
For registered Members only.
Fax
For registered Members only.
Interest YueQing, Anhui
Company Profile Hansphin Electric
URLFor registered Members only.
Rating(0 reviews)
Popular tagsoffer,remote,control,of,fan,yarndyed,sodium,order,lignosulphonate,lexmark,in

KeywordsMr. Kant Huang

Product Specifications
Specifications:
1) Name: 1 pole definite purpose contactor
2) Model number: HLC-1N
3) Contact:
a) Arrangements: 1 pole N.O. without shunt
b) Structure: double make contacts
c) Materials: silver cadmium oxide (10% to 30Amp 13% 40Amp)
d) Max. loading rating: see contact rating chart
4) Coil:
a) Coil voltage: 50/60Hz, see coil rating chart
b) Nominal resistance: see coil rating chart
c) Nominal inrush power: 5VA@60Hz, 6VA@50Hz
d) Coil temperature rise: 65oC max.
e) Class of insulation: 130oC class B
5) Operation:
a) Must operate voltage: 85% of nominal coil valtage or less
(24VAC=75% or less)
b) Must release voltage: 10% to 60% of operate voltage
c) Initial operate time: 20ms typical
d) Initial release time: 10ms typical
e) Bounce time: 0 to 10 ms typical
6) Environment:
a) Temperature range: storage and operating -40 - 65oC
7) Initial dielectric strength:
a) Between contacts and coil: 2,500VAC
b) Between poles: 2,500VAC
c) Between open contacts: 2,500VAC
8) Mechanical data (power pole termination: wire size, tightening torque):
a) #10-32 screw: 16 - 8 AWG, 22Ibf.-in.(2.49Nm)
b) Box lug: 14 - 4 AWG, 40Ibf. -in. (4.52 Nm)
9) Coil termination: dual 0.250 quick connects (6.35mm)
10) Unit weight without optional cover: 7oz (200g/m)
11) Life expectancy: depends upon duty cycle, load, and environmental
conditionals
12) Mechanical life:
a) Design requirement AR1780 = 500,000 operations
b) Min test requirement = 1,000,000 operations at 60 operations per
minute, 50% Duty cycle, 150 F and 110% of nominal coil volatage
13) Electrical life test results:
a) 40 and 50 RLA (resistive load)
b) 250,000 operations make, carry and break 100% pf. 600VAC 30 FLA rated
c) 200,000 operations make LRA 40 to 50% pf., break 125% FLA 75 to 80%
pf.@240VAC
d) 250,000 operations make, carry, break 75 to 80% pf.@240VAC
e) 250,000 operations make, carry, break 75 to 80% pf.@600VAC
40 FLA rated
f) 100,000 operations make LRA 40 to 50% pf., break 125% FLA 75 to 80%
pf.@240VAC
g) 250,000 operations make, carry, break 75 to 80%pf.@240VAC
h) 300,000 operations make, carry, break 75 to 80%pf.@600VAC

Packing: 50pcs/box


Industry Category

Quality/Safety Certifications

Delivery Lead Time

Payment & Price Terms

My Offers

Other Products

Customers

Company HistoryThrough traditional craftsmanship and engineering excellence, the Hansphin name has symbolized quality and reliability in HVAC/R, Motor Controls and Home Applications.
Business Type:: Exporter
Trade Category: 8538 Parts Switches, Automatic Circuit Breakers, Relays or Connector
Main Item/Product: HVAC parts and compressors
Main Target Region: World Wide
Representative/CEO's Name: Kant Huang
Founded Date: 2/1999
No. of Employees: 100 to 249
Capital Assets: MORE THAN 1,000,000 US$
Annual Revenue: MORE THAN 1,000,000 US$
Annual Export Rate: 70 to 80%
Annual Import Rate: 10 to 20%
Main Bank: Bank Of China
Company Dimension: Limited

Estimated Annual Sales

Number of Employees

Person in Charge

Web SiteFor registered Members only.

View Reviews and Comments

Add comment (Login required to add a comment.)
     
Your member Password    
Title  
Comment  
Enter security code  
     




Similer Products
Definite Purpose Contactor
Product Details
Product id 115661
Visits  85
Date 2006.01.29