,Laboratory Equipment, Machinery

Agriculture, Food & Beverage 12472
Automobile & Transportation 1907
Business Services 767
Chemical 6383
Computer Hardware & Software / Telecommunications 13124
Construction and Real Estate 2012
Electrical Equipment & Supplies / Security & Protection 51530
Environment and Energy 627
Furniture & Furnishings / Woods 1102
Gifts & Crafts / Toys 1828
Home, Industrial & Office Supplies 6073
Jewelry, Eyewear & Timepieces 1889
Machinery and Equipment / Industrial Supplies 62323
Medical, Health & Beauty 2325
Minerals, Metals & Materials 39415
Sports, Leisure & Entertainment 2068
Textiles & Leather Products 11236
_Others 316
trade Join free
trade trade trade
exportexportexport
Add new Product
export export
exportexportexport
Member Login
investment investment
investmentinvestmentinvestment
My Items
investment investment
investmentinvestmentinvestment
Submit URL
investment investment
investmentinvestmentinvestment
Inquiry Basket
investment investment
Suppliers
Suppliers
Berlinkauf Trade Leads / Machinery and Equipment / Industrial Supplies / Laboratory Equipment, Machinery

Welch Allyn Atlas Vital Signs Monitor




Previous   Next



Welch Allyn Atlas Vital Signs Monitor



Technical Specifications

3-LEAD OR 5-LEAD SELECTABLE ECG
Heart Rate Range: 20-250 bpm
Heart Rate Accuracy: 3 bpm or 3%, whichever is greater
Bandwidth: 0.5-40 Hz (monitor mode) or 0.05-100 Hz (extended mode)
Display Sweep Speeds: 25, 12.5 or 6.25 mm/sec

NONINVASIVE BLOOD PRESSURE
Systolic Measurement Range: 60-250 mmHg
Diastolic Measurement Range: 30-160 mmHg
Blood Pressure Accuracy: Meets AAMI SP10-1992 Standard
Operating Modes: Manual (single determination) or Automatic Mode
Cycle Interval Choices: 1, 3, 5, 10, 15, 30 or 60 minutes

PULSE OXIMETRY (NELLCOR PURITAN BENNETT)
Measurement Range: 40-100%
Accuracy: 2 digits in the range of 70-100% saturation
Pulse Rate Range: 20-250 bpm
Pulse Rate Accuracy: 3 bpm or 3%, whichever is greater

TEMPERATURE
Range: 17-50º C (62.6 -122.0º F)
Accuracy: Meets ASTM Accuracy Standards
Probe Type: YSI Series 400 Compatible

IMPEDANCE RESPIRATION
Range: 5-100 breaths per minute
Accuracy: 3 breaths per minute

END TIDAL CARBON DIOXIDE
Measurement Technique: Sidestream
Measurement Range: 0-98 mmHg
ETCO2 Accuracy: 0-40 mmHg: 3 mmHg; 41-98 mmHg 10% of reading
Breath Rate Measurement Range: 5-100 breaths per minute
Breath Rate Accuracy: 1 breath per minute or 5%, whichever is greater

GENERAL
Size: 35 cm x 23 cm x 25 cm (13.8" x 9.1" x 9.8")
Weight: 4.3-5.5 kg (9.5 -12.1 lbs) dependant on configuration
Power Requirements: 120 VAC, 50/60 Hz; 240 VAC, 50/60 Hz
Printer: Thermal array, prints waveforms and numerical trends
Battery: Lead acid, rechargeable



Add to basket
More Products in this category
More Products from company
Send Private Message
Tell-a-friend
Add your review

[Contact Information]

Posted by ecplaza.net
e-MailContact company
Address Jakarta, Jakarta Raya Jl. Sudirman No. 458
Country
Indonesia
Phone
For registered Members only.
Fax
For registered Members only.
Interest Jakarta, Jakarta Raya
Company Profile PT. Sumut Healthcare
URLFor registered Members only.
Rating(0 reviews)
Popular tagsoffer,remote,control,of,fan,yarndyed,sodium,price,pda,order,lignosulphonate

KeywordsMr. Didi Gonzales

Product Specifications
Technical Specifications

3-LEAD OR 5-LEAD SELECTABLE ECG
Heart Rate Range: 20-250 bpm
Heart Rate Accuracy: 3 bpm or 3%, whichever is greater
Bandwidth: 0.5-40 Hz (monitor mode) or 0.05-100 Hz (extended mode)
Display Sweep Speeds: 25, 12.5 or 6.25 mm/sec

NONINVASIVE BLOOD PRESSURE
Systolic Measurement Range: 60-250 mmHg
Diastolic Measurement Range: 30-160 mmHg
Blood Pressure Accuracy: Meets AAMI SP10-1992 Standard
Operating Modes: Manual (single determination) or Automatic Mode
Cycle Interval Choices: 1, 3, 5, 10, 15, 30 or 60 minutes

PULSE OXIMETRY (NELLCOR PURITAN BENNETT)
Measurement Range: 40-100%
Accuracy: 2 digits in the range of 70-100% saturation
Pulse Rate Range: 20-250 bpm
Pulse Rate Accuracy: 3 bpm or 3%, whichever is greater

TEMPERATURE
Range: 17-50º C (62.6 -122.0º F)
Accuracy: Meets ASTM Accuracy Standards
Probe Type: YSI Series 400 Compatible

IMPEDANCE RESPIRATION
Range: 5-100 breaths per minute
Accuracy: 3 breaths per minute

END TIDAL CARBON DIOXIDE
Measurement Technique: Sidestream
Measurement Range: 0-98 mmHg
ETCO2 Accuracy: 0-40 mmHg: 3 mmHg; 41-98 mmHg 10% of reading
Breath Rate Measurement Range: 5-100 breaths per minute
Breath Rate Accuracy: 1 breath per minute or 5%, whichever is greater

GENERAL
Size: 35 cm x 23 cm x 25 cm (13.8" x 9.1" x 9.8")
Weight: 4.3-5.5 kg (9.5 -12.1 lbs) dependant on configuration
Power Requirements: 120 VAC, 50/60 Hz; 240 VAC, 50/60 Hz
Printer: Thermal array, prints waveforms and numerical trends
Battery: Lead acid, rechargeable


Industry Category

Quality/Safety Certifications

Delivery Lead Time

Payment & Price Terms

My Offers

Other Products

Customers

Company History

Estimated Annual Sales

Number of Employees

Person in Charge

Web SiteFor registered Members only.

View Reviews and Comments

Add comment (Login required to add a comment.)
     
Your member Password    
Title  
Comment  
Enter security code  
     




Similer Products
GE Medical DASH 2000 Patient Monitoring Vital Signs Monitor
Welch Allyn Atlas Vital Signs Monitor
Welch Allyn AutoTymp TM262
GE Medical Dash 3000 Vital Signs Monitor
Product Details
Product id 118137
Visits  23
Date 2006.10.28