Ultra Fine Powder Coatings
FLUOROFINE 90
POLYFINE 3000
0 (#0) 51 2008.06.10 Ultra Fine Powder Coatings
Coatings
RTV Insulator Anti Flashover Coating
RTV The insulator antifouling Flashover the coating technical specification data sheet



Item

DL/T 627 Standard

Technical Property
(Test Value )

Test Method
Outward appearance

Does not have the obvious mechanical impurity, does not have the cotton wool shape precipitation, after the solidification smooth smoothly does not have the air bubble

White (red, ash, is transparent) the color mobile liquid, the coating smoothly does not have the air bubble

GB 1721-79
Solid content %

≮22

55

GB 1725-89
Viscosity s

15~60

30

GB 1723-93
Surface resistivity
Ω?m

≮1?1012

1.8?1016

GB 1410-78
Volume resistivity Ω?m

≮1?1014

1.5?1014
Relative permittivity dielectric lose tangent value

≯3.0

2.35

GB 1409-78
≯0.3%

3.0?10-3
Breakdown field value MV/m

≮15

25.6

GB 1408-78
Arc resistance s

≮180

190

GB 1411-78
Resistance to track
and erosion TMA

≥2.5

1A 2.5

GB 6553-86
Adhesion ability (drawing the cycle method )

No less 2 level

1~2 level

GB 1720-89
Abrasion resistance g

≯0.05

qualified;

GB 1768-89
Rate of water absorption
%

≯0.25

0.16

GB 1738-89
Hydrophobicity

Hydrophobic angle >90?

111.6?

DL/T627-1997
Corrosion proof

Under the acid, the alkali, the salt and the transformer oil function do not have the corrugation, falls off, bubbles, changes color and so on

The experiment does not have the corrugation to fall off bubbles changes color the phenomenon

GB 1739-89
GB 1763-89
The labor frequency arc-over voltage (dryly flashover , wet flashover ) KV

Has the coating insulator not to have the coating insulator not to have relatively to reduce

Have coat 90.3 ,
no coat 89.5

GB 775-87
Have coat 52.0 ,
no coat 49.6
Flashover resistance

U1(have paint coat)/U2
(no paint coat )>1.5

2.34(average)

GB 4585.1-84
The environment aging performance resistance

The coating should not be cracked under the natural condition, the pulverization, the skin and falls off

After the sample moves for 10 years the coating to be complete, has the good hydrophobic character

GB11206-89
Artificial accelerate ageing

Coating after 1000h artificial accelerated ageing test, is intermediate at least

1000h the salt-fog test does not have has flowed the severance according to GB/T1766 evaluates is 1 level

GB1865-80
Heat resistant denaturation experiment (adhesive force)

Bears 5 times of temperature cycles , the experiment but does not damage

Translation failed! please try again.

DL/T627-1997
Vulcanizing time

Surface dry up ≯30 min

Surface dry up 25 min

GB 6753.2-86
Full dry up ≯7days

Full dry up 72h

0 (#0) 110 2008.05.28 RTV Insulator Anti Flashover Coating
Coatings
PRTV coating
PRTV outside power equipment insulates with takes shape permanence anti flashover compound coating Technology parameter data sheet



Items

Q/HGH 019-2004 Standard

Technical Property (Test)

Test method
Outward appearance


Does not have the obvious mechanical impurity and the cotton wool shape, The coating should level, be smooth also does not have the air bubble

Toughness liquid, Does not have the impurity and the cotton wool shape, The coating is smooth also does not have the air bubble

GB 1721-1979
Viscosity s

100~200

160

GB 1723-1993
Dielectric Strength kV/mm

≮25

32.3

GB 1408-1978
Surface resistivity Ω?m
Volume resistivity Ω?m

≮1?1012

4.25?1013

GB 1410-1978
≮1?1014

2.92?1015
Relative permittivity dielectric lose tangent value

≯3.0

2.7

GB 1409-1978
≯0.3%

2.5?10-3
Arc resistance s

≮180

217

GB 1411-1978
Electricity wear and tear leaks

AC
Alternating current

≮TMA 4.5

1A 4.5

GB 6553-1986
DC
Direct current

≮TMA 3.5

1A3.5
Adhesion ability

Cementation shearing strength MPa

≮3.0

4.7

GB 13936-1992
Cycling method level

No less 2 level

1

GB1720-1989
Abrasion resistance g

≯0.05

0.035

GB 1768-1989
Ratio of Water absorption %

≯0.25

0.15

GB 1738-1989
Hydrophobicity

Hydrophobic
and level

Qav≥100?Qmin≥90?HC1~2

106?~109? HC1

DL/T810-2002
Lose property 96h

Qav≥90?Qmin≥85?HC3~4

Non showing loss
recovery characteristic

t≤24h


Water repellency characteristic 96h

Qav≥110?Q min≥100?HC2~3

14 h Hydrophobicity reach HC1 110?~115?
Erosion Resistance Test

Acid , alkali and salt , 80℃24 h

Does not have the corrugation, falls off, bubbles, changes color and so on, The adhesion is not lower than 2 levels

Does not have the corrugation, falls off, bubbles, changes color the phenomenon, The adhesion is 1 level

GB 1763-1989
transformer oil 105℃24 h

Does not have the corrugation, falls off, bubbles and so on, The adhesion is not lower than 2 levels

Does not have the corrugation, falls off, bubbles the phenomenon, The adhesion is 1 level

GB 1739-1989
Labor frequency arc-over voltage

Dry arc-over voltage kV

Has the coating insulator not to have the coating insulator not to have relatively to reduce

Paint-coat 79.2 , no 75.9

GB 775-1987
Wet arc-over voltage kV

Paint-coat 61.9, no 55.9
Flashover resistance test

U1(have paint-coat )/U2(no paint-coat )≥2.0

U1 /U2 =2.23

GB 4585.1-1984
Heat resistant denaturation experiment -40℃~+80℃,2.5h?5 times

The coating should not damage, The adhesion inspection is not lower than 2 levels

After the experiment the coating does not have bubbles, the dehiscence, falls off, Adhesion 1 level

DL/T627-1997
Salt Spray test 1700 h

The test specimen does not surpass 3 time has flowed the severance

After 1800h,Does not have has flowed the severance

GBT5892-2003
GB/SV023-2003
Does not have leaks the mark, The electricity wear and tears have not reached the porcelain glaze

Does not have leaks the mark, The wear and tears have not reached the glazed surface
Hydrophobic migration characteristic HC2~3 level

HC1~2 level
A row line of experiment passes ≥3.0MPa

3.5 MPa
Flame Resistance

FV-O level

FV-O level

GB/T13488-92
The longitudinal strength and pulls apart the elongation ratio

Strength MPa

≮4.0

5.5

GB/T528-1988
elongation %

No less 350

390
peel strength kN/m

≮12.0

17.5

GB/T529-1988
Hardness (Shao )

35~55

46

GB/T531-1999
Vulcanizing time

Surface Dry up min

20~50

35

GB6753.2-1986
Full dry up h

≯72

65
storage stability 50℃

≥45days

After 60 days ,A row line of experiment passes

GB6753.3-1986
Self Clearance property [Only requests antifouling]

After the dirty fluid cementation is dry, Strips the intensity ≯3kPa(1 level )

Peel off strength 2.3kPa(1 level )

QB/SV021-2003
Anti ?icing property [Only requests to guard against the ice]

Anti- regelation (measure)

Paint-coat ice cover measure /no paint-coat ≯30%

18.3%

QB/SV022-2003
hydration property

DC value ≮90%

91.2%


0 (#0) 80 2008.05.28 PRTV coating
Coatings
Industrial coating
Industrial coating
0 (#0) 166 2007.10.19 Industrial coating
Coatings
Exterior wall coating
Exterior wall coating
0 (#0) 184 2007.10.19 Exterior wall coating
Coatings
Interior wall coating
Interior wall coating
0 (#0) 182 2007.10.19 Interior wall coating
Coatings
RTV Insulator Anti Flashover coating
The silicon valley brand sign RTV insulator anti flashover the coating to pass, the provincial level appraisal, The nation anti Flashover the expert group to appraise,ISO9001 International quality system authentication and sign DL/T 627 complete patterns experiments; its performance index has achieved the international advanced level
0 (#0) 225 2007.09.21 RTV Insulator Anti Flashover coating
Coatings
PRTV outside power equipment insulates with takes shape permanence anti flashover compound coating
it is a kind of electrical power system uses the new electrical function material, it’s specially for the electrical network and each round, loses, uses electricity the customer to be lasting eliminates the equipment flashover thoroughly the hidden danger then to design, It’s developed jointly by the North China electric power academy of science with our company successfully.
0 (#0) 222 2007.09.21 PRTV outside power equipment insulates with takes shape permanence anti flashover compound coating
Coatings
Metal anticorrosion fluorine silicon coating
-
0 (#0) 242 2007.09.17 Metal anticorrosion fluorine silicon coating
Coatings
Organ silicon flame-resistant heat conduction high voltage insulation coating
-
0 (#0) 184 2007.09.17 Organ silicon flame-resistant heat conduction high voltage insulation coating
Coatings
RTV Insulator Anti Flashover coating
-
0 (#0) 185 2007.09.17 RTV Insulator Anti Flashover coating
Coatings
PRTV outside power equipment insulates with takes shape permanence anti flashover compound coating
-
0 (#0) 195 2007.09.17 PRTV outside power equipment insulates with takes shape permanence anti flashover compound coating
Coatings
Organ silicon flame-resistant heat conduction high voltage insulation coating/Metal anticorrosion fl
see above
0 (#0) 348 2007.06.08 Organ silicon flame-resistant heat conduction high voltage insulation coating/Metal anticorrosion fl
Coatings
RTV Insulator Anti Flashover coating/PRTV outside power equipment insulates with takes shape permane
RTV
PRTV
0 (#0) 325 2007.06.08 RTV Insulator Anti Flashover coating/PRTV outside power equipment insulates with takes shape permane
Coatings
DSA-1 Surface Active Agent for Drilling Fluid/SFB-1 Biology Thickening Agent for Drilling Agent
SFB-1
DSA-1
0 (#0) 380 2007.06.08 DSA-1 Surface Active Agent for Drilling Fluid/SFB-1 Biology Thickening Agent for Drilling Agent
Coatings
SF Fluorine Silicon Filtrate Reducer for Drilling Fluids/Silicon Stability Agent for Drilling Fluids
SF
0 (#0) 310 2007.06.08 SF Fluorine Silicon Filtrate Reducer for Drilling Fluids/Silicon Stability Agent for Drilling Fluids
Coatings
SF260 High-temperature Drilling Fluids Thinner/SF200P Fluorine silicon High-temperature Drilling Flu
SF200
SF260
0 (#0) 319 2007.06.08 SF260 High-temperature Drilling Fluids Thinner/SF200P Fluorine silicon High-temperature Drilling Flu
Coatings
SF150 Fluorine Silicon Drilling Fluids Thinner (powder)
SF150P
0 (#0) 318 2007.06.08 SF150 Fluorine Silicon Drilling Fluids Thinner (powder)
Coatings
sell AR607Pure Polyester Dulling Resin
AR607Pure Polyester Dulling Resin

AR607 is propylene ester resin which contains epoxy. It is one kind of outdoors dulling-resin powder coating. It has good dulling effect and can obtain gloss between 1 - 60% randomly, and it is suitable for dulling gloss between 1 - 30% outdoors pure polyester prowder coating.
Typical characteristics:.

-Fine levelling performance.

-Splendid weathering resistance, saltfog resistance, fire resisting quality and yellow stain resistance.

-Strong anti-shake trait
0 (#0) 255 2007.06.07 sell AR607Pure Polyester Dulling Resin
Coatings
Sell SF-688 General Modifier For Epoxy Power Coatings
SF-688 General Modifier For Epoxy Power Coatings
performance specification:
SF-688 is a kind of acrylic acid copolymer which is composed by a special process. We adopt advanced technique at home and abroad, do specialized research and development about a general-used powder coati
ng flowing control agent, which can be acted on epoxide resin powder coatings, mixed type polyester resin powder coating material, and pure polyester powder coatings.
Typical Properties:
1). Improving levelling and uniform surface behaviour
2).Incresing the soil layer surface¡¯s ability to bear aging
3). Reducing the orange peel and pinhole phenomenon
4). Incresing lubrification for the soil layer surface and the working areas¡¯ surface
5). Strengthen adhesiveness, increasing the soil layer surface hardness
Usage:
Because of different batch formulas and technics in manufacturing different powders, the dosage of this product may be added between 0.6-1.5%; Mix SF-688 powder coating together with other raw materials equably to produce the ordered powders.
0 (#0) 252 2007.06.07 Sell SF-688 General Modifier For Epoxy Power Coatings
Coatings
Sell N,N,N',N'-Tetrakis(2-hydroxyethyl)adipamide
Chemical Name & Synonyms:N,N,N',N'-Tetrakis(2-hydroxyethyl)adipamide
Molecular Weight:320.38
Formula:C14H28N2O6/(CH2CH2OH)2NOC(CH2)4CON(CH2CH2OH)2
CAS: 6334-25-4
1. The product is the compound containing the hydroxyalkyl acidamides based group, and it is also powder coating that can bear marquis, a kind of wonderful matt-finishing hardener. Compared with the matt-finishing hardener that widely using TGIC in the worldwide, this product possess low toxicity, do not activate skin, have high speed to harden, and some other excellent feature; The powder coatings that adopts this product has outstanding performances in outdoors using, and this product is ture green environmental.
2. apperance White fine powder;no order;dissolve in water
hydroxyl value 78-82 g/ equivalent;
Melting point 125-130¡æ
Volatile matter % ¡Ü1.5%
3. This product can harden hydroxide radical polyester ( generally, the acid value is between 20-50mgKOH/g; when the acid value is at 35KOH/g, it is in best condition.) When the temperature is 200¡æ, the harden time is 5 minutes; if the temperature is 150 ¡æ, time needed is 25 mintues; The best condition we commend is 180¡æ, and baking time is 15 minutes. This product is very sensitivity to benzoin, the surface can change yellow easily. To avoid this phenomenon, we should choose appropriate polyester resin and reduceBenzoin¡¯s doage.
4. F125 can be dissolved in water, please keep away from water, and keep the heal airproof to avoid dampness.
0 (#0) 0 2007.06.07 Sell N,N,N',N'-Tetrakis(2-hydroxyethyl)adipamide
Coatings
Polyamide Powder
See above
0 (#0) 375 2007.05.25 Polyamide Powder
Coatings
Cold Applied,Cold Applied Tape,Cold Applied Tape Coating,Inner Tape
Tapes specifications:
1) T-140 with 0.38mm / 15mil thickness and 50 - 230mm width
2) T-150 with 0.51mm / 20mil thickness and 50 - 230mm width
3) T-165 with 0.64mm / 25mil thickness and 50 - 230mm width
4) T-180 with 0.76mm / 30mil thickness and 50 - 230mm width
5) T-1100 with 1.02mm / 40mil thickness and 50 - 230mm width
6) T-1130 with 1.27mm / 50mil thickness and 50 - 230mm width
0 (#0) 401 2007.04.17 Cold Applied,Cold Applied Tape,Cold Applied Tape Coating,Inner Tape
Coatings
Cold Applied Tape,Cold Applied Tape Coating,Cold Applied Adhesive,Inner Tape
Tapes specifications:
1) T-140 with 0.38mm / 15mil thickness and 50 - 230mm width
2) T-150 with 0.51mm / 20mil thickness and 50 - 230mm width
3) T-165 with 0.64mm / 25mil thickness and 50 - 230mm width
4) T-180 with 0.76mm / 30mil thickness and 50 - 230mm width
5) T-1100 with 1.02mm / 40mil thickness and 50 - 230mm width
6) T-1130 with 1.27mm / 50mil thickness and 50 - 230mm width
0 (#0) 369 2007.04.17 Cold Applied Tape,Cold Applied Tape Coating,Cold Applied Adhesive,Inner Tape
Coatings
Anti-Corrosion Tape,Anti-Corrosion Product,Anti-Corrosion Material,Inner Tape
Tapes specifications:
1) T-140 with 0.38mm / 15mil thickness and 50 - 230mm width
2) T-150 with 0.51mm / 20mil thickness and 50 - 230mm width
3) T-165 with 0.64mm / 25mil thickness and 50 - 230mm width
4) T-180 with 0.76mm / 30mil thickness and 50 - 230mm width
5) T-1100 with 1.02mm / 40mil thickness and 50 - 230mm width
6) T-1130 with 1.27mm / 50mil thickness and 50 - 230mm width
0 (#0) 414 2007.04.17 Anti-Corrosion Tape,Anti-Corrosion Product,Anti-Corrosion Material,Inner Tape
Prev 25  1  2 Next 25  
Page 1 of total 2 pages
x100 Index:  1 
We have total 139353 members and 210870 Products. There have been 16295745 Product views.

Terms of Use - Link Exchange - Our Partners - Trade Organisations -
Industry Associations - FAQ - About Us - Advertise - Help  
Copyright Notice © 1998-2007 Berlinkauf.com Corporation and its licensors. All rights reserved.



Execution time:2.49387311935