Measurement and Meter
 |
Sell thermowell The bushing is a equipment which is protecting the gauge. It's insulate gauge from medjum, and increase gauges's using life. We can maintain or replace the gauge expendiently.Whole drill type outside protector can be used in the higher pressure occassion and the steel tube type can be used in the lower pressure occasion.Consumers choose it rightly should according to the different occasion's using condition(temperature,pressure,velocity of flow and so on)
|
0 (#0) |
81 |
2008.04.16 |
 |
Measurement and Meter
 |
Sell TC/RTD RTD measuring temperature use the priciple that the resistance of conductor semiconductor change according to the temperature. Its advantages are extreme accuracy. Long-distance lanuching, high or medium temperauure measuring.
Pt-RTD is characterized by its slimness, fexibility, fast thermal response time, shock resistance, high temperature, and high pressure resistance. It can be used for direct temperature measurement , or as inner core in assembly type RTD to replace traditional ones. Its temperature measuring range is -200~+500℃.
Regular RTD may cause explosion under certiain explosion atmosphere, , in such case, EPRTD must be used as temperature detector. This type of product is suitable to be used where the explosive vapor may be present in dⅡBT4 and dⅡCT5 areas.
TC measure temperature use the pyroolectricity. Its measuring range is large. And it can lanch long-distance. It use in measuring high or medium temperature.
MITC is slim, fexible, solid with fast response. It can be used for direct measurement, or used as inner element of assembled TC to replace the tradition one. It's suitable to use in narrow., inaccessible locations , and where, flexibility and fast response are required.
Regular TC may cause explosion under certiain explosion atmosphere , in such case, EPTC must be used as temperature detector. This type of product is suitable to be used where the explosive vapor may be present in dⅡBT4 and dⅡCT5 areas.
|
0 (#0) |
62 |
2008.04.16 |
 |
Measurement and Meter
 |
Sell glass industrial thermometers Glass thermometer is a measuring gauge which made according to the priciple that thermal expansion and shrink. Its advantages are extreme accuracy, sensitive response and regged deponda bitity. Electrical contact Hg thermometer can send out the message when the temperature reach or exceed (lower) the setting temperature.
Style: V-shaped, metal bushing, adjustable angle,plastic shell glass submarine, iron shell submarine
Material of insert part: cast aluminum, copper, stainless steel or be customized
Usage: chemical,pharmacy,brewing,mechanical manufacturing ,scientific research and education system, etc.
Storted medium: mercury or organic liquid.
Measuring range: mercury -30 ~ 500℃
organic liquid (blue or red) -80 ~ 200℃
|
0 (#0) |
79 |
2008.04.16 |
 |
Measurement and Meter
 |
Sell bimetal thermometers Bimetal thermometer is a measuring gauge which used bimetal piece as senor part to measure low or medium temperature. Compare to the glass thermometer, it has advantages as non-Hg, clear in reading ,durable. Widely used in machinery, chemical industry,textile,medicnery, foodstuffs,vessel and so on for measuring and controling the temperature.
1.Accuracy : 1.5
2.Measuring range :-80~+600℃
3.Thermal response time: <40s; if the diameter of the Protect =φ6mm, <30s
4.Stem pressure -rsistant : 6.4MPa
5.Protector material : 1Cr18Ni9Ti
Type:
1.electrical contact
2.adjustable angle
3.bimetal indication thermal rsistance/thermocouple
4.explosion-proof
|
0 (#0) |
70 |
2008.04.16 |
 |
Measurement and Meter
 |
Sell flowmeters Flowmeters LZB,LZJ have simple structure with low press loss, corrosive resistant type using stainless steel or fluoroplastics can resistant most corrosive acid, alkali, axidizer and solvent. DN4~10 have hose connections and DN15~100 have flange connection or on request.
GA24, DK800, VA/FA/SA these models are manufactured by special technique and equipment of KROHNE company in German.In addition to the mm graduation scale and percentage scale on the glass cone, a replaceable scale with flow units can on request be fitting to the housing.
Flowmeter LZ are flowmeters for liquids and gases . You can mount it horizontally or vertically. There are models of local indicating, long-distance data transmission, corrosive resistant, with heating device, limit switch, explosion-proof and so on. Transmission has 0~10mA analogue signal output, suitable for electro-unit combination instrument DDZ-II or DDZ-III. It has the function of flow accumulating, digital communication. On-line correcting parameter, various power supply and so on. We can provide flange and magnetic fliter on customer's request. It's widely applied to petroleum industry, chemical plant, power atation, food processing, pharmaceutical factory and water processing.
|
0 (#0) |
79 |
2008.04.16 |
 |
Measurement and Meter
 |
KL-012 Portable pH Meter Technical Specification:
Model KL-012
Range 0.00~14.00pH
Accuracy ?0.05PH
Resolution 0.01PH
Operating temperature 0℃~50℃
Automatic Temperature Compensation 0℃~50℃
Power Supply DC 9V
Dimensions 150mm?70mm?25mm
Weight 227g
|
0 (#0) |
66 |
2008.03.19 |
 |
Measurement and Meter
 |
Single Jet Liquid-Sealed Water Meter LXS-13FD~32FD |
0 (#0) |
98 |
2008.03.10 |
 |
Measurement and Meter
 |
Big Size Multi Jet Liquid-Sealed Water Meter LXS-80F~150F |
0 (#0) |
100 |
2008.03.10 |
 |
Measurement and Meter
 |
multi jet Liquid-Sealed water meter LXS-15F~50F |
0 (#0) |
112 |
2008.03.10 |
 |
Measurement and Meter
 |
Volumetric Piston Water Meter LXH-15A~20A/LXH-15B~20B |
0 (#0) |
100 |
2008.03.10 |
 |
Measurement and Meter
 |
Multi Jet Dry Type Water Meter LXSC-15E~50E |
0 (#0) |
102 |
2008.03.10 |
 |
Measurement and Meter
 |
Single Jet Dry Type Water Meter LXSC-13D-40D and LXSC-13D3-40D3 |
0 (#0) |
111 |
2008.03.10 |
 |
Measurement and Meter
 |
calipers Calipers:Vernier Calipers,Depth Gauges,Height Gauges,Digital Calipers,Special Calipers. |
0 (#0) |
82 |
2008.01.25 |
 |
Measurement and Meter
 |
0-1Vrms (50--60HZ) AC signal Isolated Amplifier: ISO-AC-P-O General Description:
ISO AC-P-O Series AC Signal Isolation Amplifier is the one can convert input AC signal (Larger signal can be converted to 0-1Vrms signal by mutual-inductor) to 4-20mA/0-20mA DC current signal in linearity proportion or 0-5V/1-5V DC voltage signal. The series can stand the mutual isolation 2.5KVDC among input, output and embedded power. The higher loading capability makes little distortion available even after long distance transmission. |
0 (#0) |
111 |
2008.01.25 |
 |
Measurement and Meter
 |
SELL USB OTDR Wavelength 1310/1550+20nm
Fiber 9/125 µm single mode fiber
Optical Connector FC/PC
Pulse width 10ns, 30ns, 100ns, 300ns, 1μs, 3μs 10μs, 20μs, auto
Dynamic Range
(dB)Effective
SNR=1
35/33dB
38/36dB
Event Dead Zone 5m
Attenuation Dead Zone 40m
Sampling Resolution 0.25,0.5,1,2m
Max. Sampling Points 128,000
Distance Accuracy ±( 2m + 3 x10-5 distance + marker resolution)
(Fiber index error not included)
Loss Accuracy ± 0.05 dB/dB or 0.1 dB (whichever greater)
Return Loss Accuracy ± 4 dB
Max. Display Range 240 km (150 mile) |
0 (#0) |
155 |
2007.09.30 |
 |
Measurement and Meter
 |
Aj Transformer Oil Tester Zhongneng Oil Purification Co.Ltd is a manufacturer of a variety of oil purification plant.
The series of insulating oil purifier that we can provide are:
Series ZY: Vacuum Insulation Oil Purifier.
Series ZY-A: Vacuum Insulation Oil Automation Purifier.
Series ZY-R: Vacuum Insulation Oil Regeneration Purifier.
Series ZYD : Double-Stage Vacuum Insulation Oil Purifier
Series ZYD-A: Double-Stage Vacuum Insulation Oil Automation Purifier
Series ZYD-R: Double-Stage Vacuum Insulation Oil Regeneration Purifier
Series of turbine oil purifier that we can provide are:
Series TY : Vacuum Turbine Oil Purifier.
Series TY-A: Vacuum Turbine Oil Automation Purifier.
Series TY-R: Vacuum Turbine Oil Regeneration Purifier.
Series of lubricating oil purifier that we can provide are:
Series LY : Vacuum lubricating Oil Purifier.
Series LY-A: Vacuum Lubricating Oil Automation Purifier.
Series LY-R: Vacuum Lubricating Oil Regeneration Purifier.
We can also provide you with diesel oil, gasoline oil and fuel oil purifier and engine oil purifier, oil tester.
|
0 (#0) |
229 |
2007.08.20 |
 |
Measurement and Meter
 |
Av Automatic Oil Tester for Transformer Oil Purifier Zhongneng Oil Purification Co.Ltd is a manufacturer of a variety of oil purification plant.
The series of insulating oil purifier that we can provide are:
Series ZY: Vacuum Insulation Oil Purifier.
Series ZY-A: Vacuum Insulation Oil Automation Purifier.
Series ZY-R: Vacuum Insulation Oil Regeneration Purifier.
Series ZYD : Double-Stage Vacuum Insulation Oil Purifier
Series ZYD-A: Double-Stage Vacuum Insulation Oil Automation Purifier
Series ZYD-R: Double-Stage Vacuum Insulation Oil Regeneration Purifier
Series of turbine oil purifier that we can provide are:
Series TY : Vacuum Turbine Oil Purifier.
Series TY-A: Vacuum Turbine Oil Automation Purifier.
Series TY-R: Vacuum Turbine Oil Regeneration Purifier.
Series of lubricating oil purifier that we can provide are:
Series LY : Vacuum lubricating Oil Purifier.
Series LY-A: Vacuum Lubricating Oil Automation Purifier.
Series LY-R: Vacuum Lubricating Oil Regeneration Purifier.
|
0 (#0) |
148 |
2007.08.15 |
 |
Measurement and Meter
 |
Diffusive Silicon Pressure Transmitter No S code name
Analogue type Smart type HH308
Diffused silicon pressure transmitter
code Design number
A1
B1 Diffused silicon sensor
Ceramics sensor
code
Pressure types
A
G
S Absolute pressure
Gauge pressure
Seal gauge pressure
code
Site indication
1
2
3
4
no
0-100% uniform scale
3 1/2 bit LCD
3 1/2 bit LED
code Measuring range
1
2
3
4
5
6
7
8
9
0 0~35kPa
0~100kPa
0~200kPa
0~350kPa
0~700kPa
0~2.0MPa
0~3.5MPa
0~7MPa
0~20MPa
0~60MPa
code
accuracy
A
B
C 0.1% F•S
0.25% F•S
0.5% F•S
code
Installation interface
1
2 M10×1.5
1/2NPT
code
Explosion-proof ways
N Ordinary non-explosion-proof
I Intrinsic safety explosion-proof
E Explosion separation
|
0 (#0) |
162 |
2007.08.02 |
 |
Measurement and Meter
 |
Sell Metal Tube Float Flowmeter Codes Measuring pipe structure A
HH-50
HH-51
HH-52
HH-53R
HH-53L
Up in and down out
Down in and up cross out
Down cross-in and up cross-out
Right in and left out
Left in and right out
Codes Connect-liquid material B
R0
R1
Rp
Ti
RL
0Cr18Ni12Mo2Ti
1Cr18Ni9Ti
PTFE ( F4 liner) ( only HH-51, HH-52, HH-53R, HH-53L)
Ti alloy (only HH-51, HH-52, HH-53R, HH-53L )
316L
Codes Pipe caliber C
DN15
DN25 DN50
DN80 DN100
DN150
DN200
15
25
50
80
100
150
200
Codes Additional structure D
No
T Clamp cover type (only HH-51, HH-52, HH-53R, HH-53L)
Z Damping type
G Hi-temperature type
Y Hi-pressure type
Code
Indicator formal codes combination
E See the following sheet
HH-50 R0 DN50 G E
Measuring pipe structure A Connect-liquid
material B Pipe caliber C Additional structure D
50 Down in and up out R0
R1
Rp
Ri
RL 0Cr18Ni12Mo2Ti
1Cr18Ni9Ti
PTFE (F4 liner)
Ti alloy
316L DN15
DN25 DN50
DN80 DN100
DN150
DN200 No
T Clamp cover type
Z Damping type
G Hi-temperature type
Y Hi-pressure type
51 Down in and up crossout
R0
R1
RL
0Cr18Ni12Mo2Ti
1Cr18Ni9Ti
316L DN15
DN25 DN50
DN80 DN100
DN150
DN200 No
Z Damping type
G Hi-temperature type
Y Hi-pressure type
52 Down cross-in and up cross-out
R0
R1
RL 0Cr18Ni12Mo2Ti
1Cr18Ni9Ti
316L DN15
DN25 DN50
DN80 DN100
DN150
DN200 No
Z Damping type
G Hi-temperature type
Y Hi-pressure type
53R
53L Right in and left out
Left in and right out R0
R1
RL 0Cr18Ni12Mo2Ti
1Cr18Ni9Ti
316L DN15
DN25 DN50
DN80 DN100
DN150
DN200 No
Z Damping type
G Hi-temperature type
Y Hi-pressure type
E HHD indicator form codes combination
M1 On-the-spot indicator, square shell body, machanical pointer displays instant flow * flow rate
M2 Power supply type square shell body, machanical pointer displays instant flow rate
M3 Power supply-type round shell body, no machanical pointer indicates, liquid crystal indicates instant/accumulated flow rate
Ways of power supply
No Only for M1 indicator
A 220VAC 50Hz power supply,4-20mA signal output, back light allowed
B Battery power supply, no signal output
C 24VDC two-wire system power supply, 4-20mA signal output, no back light
D 24VDC three –or- four-wire system power supply, 4-20mA signal output, back light allowed
Explosion-proof symbol
No Ordinary non-explosion-proof
1 Intrinsic safety type ia II CT5 square shell body
d Explosion separation type d II BT4 round shell body
C alarm or impulse output
No No alarm or impulse output
K1 Upper-limit alarm or one-way impulse output
K2 Lower-limit alarm or one-way impulse output
K3 Upper-limit or Lower-limit alarm or two-way impulse output
|
0 (#0) |
146 |
2007.08.02 |
 |
Measurement and Meter
 |
Sell Flange Type Level Transmitter No S Code(single-level flange) Measuring range Code (single insert flange) Measuring range
Analogue type Smart type HHLT-3310
HHLT-4410
HHLT-4510
HHLT-4610
HHLT-4710 0-1.2-7.2kPa
0-6-36kPa
0-30-180kPa 0-160-1000kPa 0-400-2500kPa HHLT-3330
HHLT-4430
HHLT-4530
HHLT-4630
HHLT-4730 0-1.2-7.2kPa
0-6-36kPa
0-30-180kPa 0-160-1000kPa 0-400-2500kPa
Code Assembling flange specification Code Assembling flange specification
A
B
C
D 3 ” 1501b
4 ” 1510b
3 ” 1501b
4 ” 1501b A0
B1
C2
D3 0
50
100
150
Codes Optional components
M1 Linear indication gauge 0-100% scale mark
M2 Digital indication gauge head
B1 Pipe-assembling bend stand (2” pipe)
B2 Plate- assembling bend stand
B3 Pipe-assembling level stand (2” pipe)
D1 Flange profile plane exhausting valve on the above part
D2 Flange profile plane exhausting valve on the below part
E1 Average cable connector
E2 Explosion-proof cable connector
G1 Waist type flange
G2 Welding pipe connector
d Explosion separation type Exds II BT5
i
Intrinsic safety type Ex ia II CT5
|
0 (#0) |
176 |
2007.08.02 |
 |
Measurement and Meter
 |
Absolute Pressure Transmitter No S modes Measuring range
Analogue type Smart type HHAP-1200
HHAP-1300
HHAP-1400
HHAP-1500
HHAP-1600 0-6~40kPa
0-40~250kPa
0-0.16~1MPa
0-0.4~2.5MPa
0-1.6~10MPa
codes Structure material
Flange connector Exhausting valve Isolating
membrane Filling Liquid
F12 Carbon steel
Cd-plating 316L stainless steel 316L
stainless
steel
Silicaoil
F13 Carbon steel
Cd-plating HC H HC
F14 Carbon steel
Cd-plating Monel Monel
F15 Carbon steel
Cd-plating 316L stainless steel Ta
F22 316L stainless steel 316L stainless steel 316L stainless steel
F23 316L stainless steel 316L stainless steel HC
F24 316L stainless steel 316L stainless steel Monel
F25 316L stainless steel 316L stainless steel Ta
F33 HC HC HC
F35 HC HC Ta
F44 Monel Monel Monel
code
Additional functions
M1 Linear indication gauge 0-100% scale mark
M2 Digital indication gauge head
B1 Pipe-assembling bend installation board
B2 Plate- assembling installation board
B3 Pipe-assembling level installation board
C0 1/2-14NPT inside cone pipe thread connector
C1 1/2-14NPT ignition voltage connector backward welding innition voltage pipe Ø14
C2 T-shaped thread connector M20×1.5
d Explosion separation type d II BT4
i Intrinsic safety type ia II CT6
S HHAP-2600 F12 M3B1C2i 1MPa (factory span)
|
0 (#0) |
147 |
2007.08.02 |
 |
Measurement and Meter
 |
Sell Differential Pressure Transmitter No S Codes Measuring range Working pressure(MPa)
Analogue type Smart type HHDP-3300
HHDP-5300
HHDP-5400
HHDP-5500
HHDP-6400
HHDP-6500
HHDP-9600
HHDP-9700
HHDP-8800 0-1.2~7.2kPa
0-1.2~7.2kPa
0-6~36kPa
0-30~180kPa
0-6~36kPa
0-30~180kPa
0-160~1000kPa
0-400~2500kPa
0-1600~10000kPa 2.5
6.4
6.4
6.4
16
16
40
40
32
codes Structure material
Flange connector Exhausting valve Isolating membrane Filling Liquid
F12 Carbon steel
Cd-plating 316L stainless steel 316L stainless steel
Silica oil
F13 Carbon steel
Cd-plating HC HC
F14 Carbon steel
Cd-plating Monel Monel
F15 Carbon steel
Cd-plating 316L stainless steel Ta
F22 316L stainless steel 316L stainless steel 316L stainless steel
F23 316L stainless steel 316L stainless steel HC
F24 316L stainless steel 316L stainless steel Monel
F25 316L stainless steel 316L stainless steel Ta
F33 HC HC HC
F35 HC HC Ta
F44
Monel Monel Monel
codes Optional components
M1 Linear indication gauge 0-100% scale mark
M2 Digital indication gauge head
B1 Pipe-assembling bend stand (2” pipe)
B2 Plate- assembling bend stand
B3 Pipe-assembling level stand (2” pipe)
D1 Flange profile plane exhausting valve on the above part
D2 Flange profile plane exhausting valve on the below part
E1 Average cable connector
E2 Explosion-proof cable connector
G1 Waist type flange
G2 Welding pipe connector
d Explosion separation type Exds II BT5
i Intrinsic safety type Exib II CT5
S HHDP-3300 F12 M1B1D1E1G1d 6kPa (factory span)
|
0 (#0) |
156 |
2007.08.02 |
 |
Measurement and Meter
 |
Sell Pressure Transmitter No S Modes Measuring range
Analogue type Smart type HHGP-1200
HHGP-1300
HHGP-1400
HHGP-1500
HHGP-1600
HHGP-1700
HHGP-1800
HHGP-1900
HHGP-1000 0-0.25~1.5kPa
0-1.2~7.2kPa
0-6~36kPa
0-30~180kPa
0-160~1000kPa
0-400~2500kPa
0-1600~10000kPa
0-4000~25000kPa
0-7000~40000kPa
Codes Structure material
Flange connector Exhausting valve Isolating membrane Filling liquid
F12 Carbon steel
Cd-plating 316L stainless steel 316L stainless steel
F13 Carbon steel
Cd-plating HC HC
F14 Carbon steel
Cd-plating Monel Monel
Silica oil
F15 Carbon steel
Cd-plating 316L stainless steel Ta
F22 316L stainless steel 316L stainless steel 316L stainless steel
F23 316L stainless steel 316L stainless steel HC
F24 316L stainless steel 316L stainless steel Monel
F25 316L stainless steel 316L stainless steel Ta
F33 HC HC HC
F35 HC HC Ta
F44
Monel Monel Monel
code Optional components
M1 Linear indication gauge 0-100% scale mark
M2 Digital indication gauge head
B1 Pipe-assembling bend stand (2” pipe)
B2 Plate- assembling bend stand
B3 Pipe-assembling level stand (2” pipe)
D1 Flange profile plane exhausting valve on the above part
D2 Flange profile plane exhausting valve on the below part
E1 Average cable connector
E2 Explosion-proof cable connector
G1 Waist type flange
G2 Welding pipe connector
d Explosion separation type Exds II BT5
i
Intrinsic safety type Exib II CT5
S HHGP-1200 F12 M1B1D1E1G1d 1kPa (factory span)
|
0 (#0) |
133 |
2007.08.02 |
 |
Measurement and Meter
 |
Sell Electromagnetic Flowmeter Electromagnetic flowmeters are applied to measure the volume flowrate of conductive liquid and serosity serum in seal pipes. They are fitting for petro chemistry, steel-iron metallurgy, feedwater and draining, water irrigation, water disposition, controling of the total amount of sewage, electric power, paper making, pharmaceutical, food, etc, sectors. |
0 (#0) |
147 |
2007.08.02 |
 |
Measurement and Meter
 |
thermocouple We would like to draw your attention on our company,
BROIL SENSOTEK INDUSTRIES, Producer of special application fine RTD and THERMOCOUPLE. and all india Distributor of SENSOR-TECH( Europe)/ Auto Tran( USA) . PRESSURE TRANSMITTER
PRESSURE TRANSMITTER:
ALL WETTED PART: S.S-316
ACCURACY: 0.25 %/ 0.5%/ 0.1%
RANGE: 0- 250 mbar------2000 bar
Output signal: 4 . .20 mA, 0 .. 5 Vdc, 0 .. 10 Vdc, other on request
Power supplier: 10 ... 28Vdc (Current Output)
15 .. 30 Vdc (Voltage Output)
Process connection: G1/4 or G1/2
TEMPERATURE SENSOR:
RTD-PT-100/ THERMOCOUPLE-J/K/R/S/T
Type : Simplex/ Duplex
Sheath Dia : 2/4/6/8/10/12-----30 mm
Sheath Length : 2 inch------5 METER
Sheath Mterial : SS-316/ S.S-310/ S.S-310/ INCONEL/PORCELINE/CERAMIC/ALUMINA
Accuracy : As Per Din/ANSI Std.
Head :Cast Al. / bare wire/coneector
Connection : Threaded/Flange
We Are Also Deal In
LOAD CELL, DIFFERENTIAL PRESSURE TRANSMITTER,
DIGITAL INDICATOR, CONTROLLER ,
PID BASE CONTROLLER. LOOP INDICATOR
In case our products are able to match your needs, do not hesitate to
contact us,
We will be happy to serve you in the best possible way,
|
0 (#0) |
86 |
2007.06.12 |
 |
|